For high-sensitivity detection of phosphorylated proteins

Phos-tag Mass Analytical Kit

00906_img01.gif

Phos-tag Mass Analytical Kit is used by mixinged with MALDI-TOF/MS samples before use. Phos-tag - phosphorylated molecule complex is detected in a positive mode with high sensitivity, including phosphorylated molecules that are otherwise difficult to detect.

Application

Detection of Phos-tag - Phosphorylated LPA Complex

00906_img02.png
LPA2- :1-oleoyl-L-α-lyzophosphatidate (MW: 434.2)

Increased positive charge improved the detection sensitivity for phosphorylated LPA.

Kit Components

Kit Components Molecular Formula MW Package Volume
Phos-tag MS-101L [(C27H29N6O64Zn2]3+ 581.4 5 mg
Phos-tag MS-101H [(C27H29N6O68Zn2]3+ 589.4 5 mg
Phos-tag MS-101N [(C27H29N6OZn2]3+ 584.3 10 mg

References

  1. "Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry of phosphorylated compounds using a novel phosphate capture molecule", H. Takeda, A. Kawasaki, M. Takahashi, A. Yamada, and T. Koike, Rapid Commun. Mass Spectrom., 2003, 17, 2075-2081.
  2. "Production of 1,2-Didocosahexaenoyl Phosphatidylcholine by Bonito Muscle Lysophosphatidylcholine/Transacylase", K. Hirano, H. Matsui, T. Tanaka, F. Matsuura, K. Satouchi, and T. Koike, J. Biochem., 2004, 136, 477-483.
  3. "Quantitative analysis of lysophosphatidic acid by time-of-flight mass spectrometry using a phosphate capture molecule", T. Tanaka, H. Tsutsui, K. Hirano, T. Koike, A. Tokumura, and K. Satouchi, J. Lipid Res., 2004,45,2145-2150.
  4. "Formation of lysophosphatidic acid, a wound-healing lipid, during digestion of cabbage leaves", T. Tanaka, G. Horiuchi, M. Matsuoka, K. Hirano, A. Tokumura, T. Koike, and K. Satouchi, Bioscience, Biotechnology, and Biochemistry,2009,73, 1293-1300.
  5. "A clean-up technology for the simultaneous determination of lysophosphatidic acid and sphingosine-1-phosphate by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using a phosphate-capture molecule, Phos-tag", J. Morishige, M. Urikura, H. Takagi, K. Hirano, T. Koike, T. Tanaka, and K. Satouchi, Rapid Communications in Mass Spectrometry, 2010, 24, 1075-1084.

Product List

  • Open All
  • Close All

Related Product List

  • Open All
  • Close All

For research use or further manufacturing use only. Not for use in diagnostic procedures.

Product content may differ from the actual image due to minor specification changes etc.

If the revision of product standards and packaging standards has been made, there is a case where the actual product specifications and images are different.

The prices are list prices in Japan.Please contact your local distributor for your retail price in your region.

Please contact us via the inquiry form.